Interconnection and cross-connects in a data center: how it works

Once your servers are racked, they still need to reach the world: carriers, internet exchanges, your other sites. In a data center this physical link has a name, the cross-connect, and it weighs on the bill as much as on performance.

Le cross-connect en colocationVotre baieMeet-Me RoombrassageCarrier / IXPa dedicated cable, billed monthly
The cross-connect: the physical cable that links your rack to a carrier or an internet exchange, through the interconnection room (Meet-Me Room).
Estimate my cost →

A cross-connect is a physical cable, copper or fibre, that links your rack to another party present in the data center: a carrier, an internet exchange, another customer. It runs through the interconnection room, the Meet-Me Room, where the links concentrate. It is the basic building block of all colocation connectivity.

The Meet-Me Room, the data center's crossroads #

The Meet-Me Room (MMR) is the neutral room where all present carriers come to connect. Being well connected there means reaching many networks easily. A data center rich in carriers in its MMR offers more choice and better transit prices.

What a cross-connect costs #

A cross-connect is usually billed at install, then monthly, per link. This recurring cost, often underestimated, adds up fast: multiplying links, for several carriers or for redundancy, multiplies the bill. Worth comparing between data centers, as pricing varies widely.

Direct or dedicated patching #

On the internal cabling side, two schools. Direct interconnection links the equipment to the distribution panel in a single patch: simple, cheap, low loss. The cross-connect in the cabling sense adds a dedicated patch panel that mirrors the ports: more hardware and space, but an isolated patching zone that protects critical equipment and simplifies changes.

Why dedicated patching reassures #

With a dedicated patching zone, you never touch the active equipment ports again: adds and moves happen on the jumpers, between panels. The result is fewer mistakes and faster incident recovery. That is why critical environments prefer it, despite the extra cost.

What it means for your hosting #

Before choosing a data center, look at who is present in its Meet-Me Room, the price and lead time of a cross-connect, and the possible redundancy, with two links over two paths. A site poor in carriers locks you in, a rich one gives you choice. An interconnection comparator makes this visible before you sign.

FAQ #

Cross-connect or plain network cable, what is the difference?

A cross-connect is a dedicated physical link, installed and maintained by the data center between two precise points, for example your rack and a carrier. It goes beyond a cable you plug in yourself: it runs through the interconnection room and is billed monthly.

What is the Meet-Me Room?

The neutral room of a data center where all carriers come to connect. It is where networks meet, and therefore where you go to get your connectivity.

How many cross-connects do I need?

At least two if you want resilience: two links to two separate carriers, over two paths. Each extra link improves redundancy but adds to the monthly bill.

Written on 1 September 2026.

From reading to comparing: relevant data centers

Telehouse - Paris 2 (Voltaire - Léon Frot)
Paris · 356 networks on site · certified ISO 27001, PCI DSS
See the exact price →
Equinix PA2 - Paris, Saint-Denis
Paris · 146 networks on site · certified HDS, ISO 22301
View the listing →
Equinix PA3 - Paris, Saint-Denis
Paris · 122 networks on site · certified HDS, ISO 22301
View the listing →
UltraEdge Lyon-Venissieux
Vénissieux · 83 networks on site · certified ISO 27001, ISO 50001
View the listing →

Estimate my cost →   Compare data centers

Other guides

Guides · Expert answers →

Advertisement